Abstract

In this paper results of an absorption heat storage cycling test are presented. The specific application is long term heat storage, the test setup is based on a spiral finned tube heat and mass exchanger constructed of stainless steel type 1.4571 and the absorbent working pair is sodium hydroxide and water. A total of 7 cycles are performed at approximately 13.5 hours of absorption and 17 hours of desorption time per cycle. Average concentration of sodium hydroxide in the solution is 48 wt% after desorption and 27 wt% after absorption. Comparison of thermal performance among different cycles is made. No clear tendency of cycling improvement or degradation is found.