Evaluation of an Integrated Pipe Water Cooling Strategy to Improve BIPV Structure Performance

Gendler, I., Leandro, M., Albazi, R., Henriquez, R., Sanghvi, J., Singh, R., Eranki, G. A., Zaidi, S. H.

Solar 2019 · Minneapolis, MS · 2019-08-05
Published by International Solar Energy Society (ISES)
DOI: 10.18086/solar.2019.01.01

Abstract

When the temperatures of photovoltaics break a threshold of 25 degrees celsius, they begin to lose efficiency. This work describes the basis of a water cooling mechanism which may be used to cool down roof mounted photovoltaics. After a thorough literature review, it was decided that running water through aluminum pipes attached to the back of a solar panel would be the most effective method. To study the effectiveness of such a system, a prototype was fabricated two panels were brought out to the top of a solar deck in an engineering university building and laid out in parallel. One panel had the cooling system attached to its back and the other one had no attachments to serve as a control panel. Experimentation was performed by taking temperature measurements for one hour before activating the hydraulics for 30 minutes. It was found that a significant reduction of temperature occurred on the water-cooled panel.

Keywords

Solar power, Buildings, Thermodynamics, Cooling

Download full text (PDF)

← All proceedings papers