From 76.6 to 80.1 %; PV-System Performance-Ratio in Mexio City

Matsumoto, Yasuhiro, Asomosa, René, Luna Arias, Miguel Angel, Ortega López, Mauricio, Dorantes Rodrígues, José Rubén, Peña Sierra, Ramon, Urbano Castelán, José A.

ISES Solar World Congress 2019 · Santiago, Chile · 2019-11-04
Published by International Solar Energy Society (ISES)
DOI: 10.18086/swc.2019.16.05

Abstract

During 2017 and 2018, performance ratio (PR) of the 60 kWp photovoltaic-system (PVS) was evaluated at the north location of Mexico City. The solar irradiation was detected using the thermopile-pyranometer installed in a plane of array (POA) of PV panels. The average daily generated energy for 2017 was 261.65 kWh/day, with a PR of 80.1%. For 2018, the generated energy was 254.79 kWh/day with a PR of 76.6%. The day-time average PV module temperature during 2017 was 34.8 ºC and 35.6 ºC for 2018. Soiling effect in PV-array was also measured, indicating about a 20 % of PR reduction.

Download full text (PDF)