A Numerical Model to Evaulate the Flow Distribution in Large Solar Collector Fields in Different Operating Conditions

Bava, Federico, Furbo, S, Dragsted, Janne

EuroSun 2016 · Palma de Mallorca, Spain · 2016-10-11
Published by International Solar Energy Society (ISES)
DOI: 10.18086/eurosun.2016.05.05

Abstract

A numerical model to evaluate the flow distribution in a large solar collector field was developed in Matlab and is presented in this study. Model and measurements from a solar collector field were compared and a good agreement was found. The model was then used to study the flow distribution in different array layouts. Balancing valves proved to be an effective way to achieve uniform flow distribution also in conditions different from those for which the valves were regulated, as well as in case of irregular layouts with different compositions of the collector rows. A Tichelmann connection gave a uniform flow distribution, especially if the distribution pipe diameter is reduced so to give a constant pressure drop gradient. The reduction in power output from the collector field was approximately proportional to the square of the root-mean-square deviation of the flow distribution, but was generally small, at least under the considered assumptions.

Keywords

Solar collector, Solar collector field, Flow balancing, Flow distribution, Parallel connection

Download full text (PDF)